12 soarten respiratoire patogenen
Produktnamme
HWTS-RT071A 12 soarten respiratoire patogenen Nukleïnezuurdeteksjekit (fluoreszinsje-PCR)
Kanaal
Kanaal | hu12Reaksjebuffer A | hu12Reaksjebuffer B | hu12Reaksjebuffer C | hu12Reaksjebuffer D |
FAM | SARS-CoV-2 | HADV | HPIV Ⅰ | HRV |
VIC/HEX | Ynterne kontrôle | Ynterne kontrôle | HPIV II | Ynterne kontrôle |
CY5 | IFV A | MP | HPIV Ⅲ | / |
ROX | IFV B | RSV | HPIV Ⅳ | HMPV |
Technyske parameters
Opslach | ≤-18 ℃ |
Hâldberens | 12 moannen |
Spesimentype | Orofaryngeale swab |
Ct | ≤38 |
CV | ≤5.0% |
LoD | SARS-CoV-2: 300 eksimplaren/mlgrypfirus B: 500 eksimplaren/mlgrypfirus A: 500 eksimplaren/ml Adenovirus: 500 kopyen/ml mycoplasma pneumoniae: 500 kopyen/ml respiratoir syncytial firus: 500 kopyen/ml, parainfluenzavirus (Ⅰ, Ⅱ, Ⅲ, Ⅳ): 500 kopyen/mL Rhinovirus: 500 kopyen/ml minsklik metapneumovirus: 500 kopyen/ml |
Spesifisiteit | De krúsreaktiviteitsstúdzje lit sjen dat der gjin krúsreaktiviteit is tusken dizze kit en enterofirus A, B, C, D, epstein-barr-firus, maselsfirus, minsklik cytomegalofirus, rotavirus, norovirus, boffirus, varicella-herpes zoster-firus, bordetella pertussis, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans en minsklik genomysk nukleïnezuur. |
Tapasselike ynstruminten | Applied Biosystems 7500 Real-Time PCR SystemenApplied Biosystems 7500 Snelle Real-Time PCR-systemenQuantStudio®5 Real-Time PCR-systemen SLAN-96P Real-Time PCR-systemen (Hongshi Medical Technology Co., Ltd.) Ljochtsykler®480 Real-Time PCR-systeem, LineGene 9600 Plus Real-Time PCR-deteksjesysteem (FQD-96A, Hangzhou Bioer-technology) MA-6000 Real-Time Kwantitative Termyske Sykler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Real-Time PCR-systeem BioRad CFX Opus 96 Real-Time PCR-systeem |
Wurkstream
Opsje 1.
Oanrikkemandearre ekstraksjereagens: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) fan Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., De ekstraksje moat strikt neffens de ynstruksjes útfierd wurde.
Opsje 2.
Oanrikkemandearre ekstraksjereagens: Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) en Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B) fan Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., de ekstraksje moat strikt neffens de ynstruksjes útfierd wurde. It oanrikkemandearre eluasjevolume is 80μL.
Opsje 3.
Oanrikkemandearre ekstraksjereagens: Nucleic Acid Extraction or Purification Kit (YDP315) fan Tiangen Biotech (Beijing) Co., Ltd., de ekstraksje moat strikt neffens de ynstruksjes útfierd wurde. It oanrikkemandearre eluasjevolume is 100 μL.